Fleet
NormalWarningAlarm
Pumps online
—
Fleet health index
—
Active alerts
—
Data completeness 24 h
—
Alerts & recommendations
Vibration trend · pump bearing housing
Velocity RMSWarningAlarm
Envelope spectrum · latest capture
Motor current & load (MCSA)
Current, A
Automatic diagnosis
Confidence
Recommended action window
Evidence
Recommendation
Similar cases in failure history
Captures · 30 days
Time waveform · acceleration, g
Spectrum
Envelope spectrum · band 2–5 kHz, g
Drag on a chart to zoom · double-click to reset · hover for values
Equipment
Measuring point
Pump bearingMotorDrive
Parameters
Period
6 h24 h7 days30 days
Trends
Values
Rules on this site
Sites & equipment
Failure events analysed
—
Mean time between failures · fleet
—
Unplanned share of repairs
—
Components with new strategy
4 / 6
Failure causes · Pareto · click a bar
EventsCumulative %
Mean run time between failures by component, h
■ weakest components → first candidates for condition-based maintenance
Maintenance strategy · current vs recommended
| Component | Current practice | Recommended |
|---|---|---|
| Pump bearings | Replace every 6 months | Condition-based (vibration) + lubrication check every 2 weeks |
| Belt drive | Replace every 3 months | Condition-based (slip monitoring), tension check on alert |
| Impeller | Inspect every 1 000 h | Inspect when load / current drift > 8 % |
| Liners | Run to failure | Inspect every 1 500 h based on wear rate |
| Seal / gland | Repack on visible leak | Seal check added to 2-week lubrication round (RCA finding) |